Find the Hypot that’s Right for You

Models 3805 3855 3865 3870
Test Capabilities AC Hipot
Ground Continuity
AC Hipot
Ground Continuity
Insulation Resistance
AC Hipot
DC Hipot
Ground Continuity
AC Hipot
DC Hipot
Ground Continuity
Insulation Resistance
Test Specifications AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω
AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω

Insulation Resistance
Voltage Output = 30-1000VDC
Resistance Range = 1MΩ-50GΩ
AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz

DC Hipot
Voltage Output = 0-6000VDC
Leakage Current Limits = 1µA-7.500mA
DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω
AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz

DC Hipot
Voltage Output = 0-6000VDC
Leakage Current Limits = 1µA-7.500mA
DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω

Insulation Resistance
Voltage Output = 30-1000VDC
Resistance Range = 1MΩ-50GΩ
Safety Safety Interlock
SmartGFI®
Security Access
Safety Interlock
SmartGFI®
Security Access
Safety Interlock
SmartGFI®
Security Access
Safety Interlock
SmartGFI®
Security Access
Productivity Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®
Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®
Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®
Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®
Automation USB USB USB USB
Warranty Standard 5 Year Warranty Standard 5 Year Warranty Standard 5 Year Warranty Standard 5 Year Warranty
Production Test Compliance IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
Type Test Compliance BS EN 60204-1
IEC/UL 60601-1
IEC 61730-1
UL 1703
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
BS EN 60204-1
IEC/UL 60601-1
IEC 61730-1
UL 1703
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
BS EN 60204-1
IEC/UL 60601-1
IEC 61730-1
UL 1703
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
BS EN 60204-1
IEC/UL 60601-1
IEC 61730-1
UL 1703
UL 2202
UL 1598/CSA C22.2 No. 250.0-08
In the Box Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key
Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key
Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key
Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key
Instrument Dimensions 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm) 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm) 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm) 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm)
Weight 12 lbs (5.46 kg) 12 lbs (5.46 kg) 12 lbs (5.46 kg) 12 lbs (5.46 kg)
Shipping Dimensions & Weight (out-the-door) Dimension: 19 x 15 x 10 in
Weight: 14 lbs (7 kg)
Dimension: 19 x 15 x 10 in
Weight: 14 lbs (7 kg)
Dimension: 19 x 15 x 10 in
Weight: 14 lbs (7 kg)
Dimension: 19 x 15 x 10 in
Weight: 14 lbs (7 kg)